Hitachi ZX240-5G, ZX240LC-5G, and ZX250LCH-5G Excavator Manual
Product Overview
This comprehensive service manual is designed for the Hitachi Excavator models listed below. It offers detailed information and guidance on operation, troubleshooting, and maintenance.
- ZX240-5G
- ZX240LC-5G
- ZX250H-5G
- ZX250LCH-5G
The manual is available in PDF format and is written in English. It includes:
- Troubleshooting Manual: Volume No. TODCE-EN, 438 Pages
- Operation Manual: Volume No. TTDCE-EN, 348 Pages
- Workshop Manual: Volume No. WDCE-EN, 502 Pages
- Circuit Diagram: 13 Pages
Note: Measurements are provided in SI Units (International System of Units).
Manual Guide Composition
The service manual is divided into distinct sections to enhance usability:
- Service Manual: Contains essential information for operational performance tests, device activation, and troubleshooting techniques.
- Workshop Manual: Provides guidance on maintenance and repair, including necessary tools, maintenance standards, and procedural instructions for assembly and disassembly.
Benefits
- Access cutting-edge hydraulic technology with superior performance metrics.
- Enjoy reduced fuel consumption and high durability for cost-effective operation.
- Insight into troubleshooting through detailed fault code guidelines.
Usage Recommendations
- Ensure safe operation by referring to the service manual and using correct lifting equipment for heavy components.
- Utilize the fault code instructions for effective troubleshooting and repairs.
Fault Code Manual Instructions
Fault Code: 14001-2
Trouble: Flash Memory Read/Write Error
Cause: Anomaly in the internal memory of the monitor controller.
Remedy: Initialize the monitor controller using MPDr. If the error persists, replace the monitor controller as stored data will be lost during initialization.
Fault Code: 14006-2
Trouble: Communication Terminal: Communication Error
Cause: Communication line issues with the terminal.
Remedy: Inspect communication and power lines and fuses. Retry troubleshooting using MPDr. If the fault remains, replace the communication equipment.